Laversab 6300 RVSM Automated Pitot Static Tester (Most Versatile 2-Ch Tester)
	Laversab 6300 RVSM Automated Pitot Static Tester (Most Versatile 2-Ch Tester).The Model 6300 is a versatile 2-channel RVSM Pitot Static Tester targeted for General Aviation; all Business Jets and Commercial Aircraft. It is used to perform leak-checks and accuracy checks on the Pitot Static systems of RVSM aircraft up to 690 knots & 60,000 ft. Accuracy checks are typically performed on altimeters, airspeed indicators and VSI’s. The Model 6300 is equipped with a Remote unit with large keypad and display, a removable 8-hour battery (optional), wide operating temperature (optional), and “profiles” to accelerate testing. Calibration is required only once a year. The 6300 can be controlled by an iPad or other tablets.
SIMPLIFY
- Automated tests with profiles
 - Wi-Fi control from tablet
 - Leak check in minutes
 
PERFORM
- Wired remote & Wi-Fi included
 - 8-hour removable battery (opt.)
 - Extended temperature ranges (opt.)
 
PROTECT
- Emergency vents
 - Large leak defense
 - Self test for integrity
 - Programmable limits
 
STATIC OUTPUT
	Pressure function:     Range:               1 to 32 inHg
	                                  Resolution:         0.001 inHg
	                                  Accuracy:           ±0.002 inHg
	                                  Units:                 inHG, mbar,psi,mmHG, kpa
	Pressure Rate:          Range:               0 to 30 inHg/min
	                                  Resolution:         0.001 inHg/min
	                                  Accuracy:           ±1% of rate
	                                  Units:                 pressure-units/min
	Altitude function:       Range:               -2000 ft. to 60,000 ft.
	                                  Resolution:        1 foot
	                                  Accuracy:          ± 3 ft. @ 0 ft.
	                                                            ± 4 ft. @ 10,000 ft.
	                                                            ± 6 ft. @ 20,000 ft.
	                                                            ± 9 ft. @ 35,000 ft.
	                                                            ± 18 ft. @ 50,000 ft.
	                                 Units:                  Feet, Meters
	Climb function:         Range:                0 ft/min to ±15,000 ft/min
	                                 Resolution:         1 ft/min
	                                 Accuracy:            ±1% of rate of climb
	                                 Units:                  Feet/min, Meters/sec
	PITOT OUTPUT
	Pressure Function:    Range:              0 to 30 inHg
	                                  Resolution:        0.001 inHg
	                                  Accuracy:          0 .003 inHg
	                                  Pt Units:            inHg, mbar,psi,mmHg, kpa, EPR
	                                  Qc Units:           inHg, mbar,psi,mmHg, kpa
	Pressure Rate:          Range:              0 to 30 inHg/min
	                                  Resolution:        0.001 inHg/min
	                                  Accuracy:          ±1% of rate
	                                  Units:                pressure-units/min (EPR in inHg/min) 
	Airspeed Function:    Range:              0 to 690 knots
	                                  Resolution:        0.1 knots
	                                  Accuracy:          ± 1.0 knots @ 20 knots
	                                                            ± 0.3 knots @ 50 knots
	                                                            ± 0.2 knots @ 100 knots
	                                                            ± 0.1 knots @ 200 knots
	                                                            ± 0.04 knots @ 500 knots
	                                  Units:                knots, Mach, km/hr, mph
	                                  Rate of change:          0 to 500 knots/min
	Airspeed Rate:          Range:               0 to 500 knots/min
	                                  Resolution:        0.1 knots/min (0.01 km/hr/sec)
	                                  Accuracy:          ±2% of rate
	                                  Units:                knots/min, km/hr/sec, mph/min
	Mach Function:         Range:              0.0 to 3.0 Mach
	                                  Resolution:        0.001 Mach
	                                  Accuracy:          ±0.001 above 0.2 Mach
	Power Requirement:         90-260 VAC, 47-440 Hz, 100 W (200 W with heaters)
	                                         Optional Removable Battery: 6 to 8 hours of operation
	External Interfaces:          WiFi, RS232 Serial ; Encoder optional
	Dimensions & weights:     Main unit:        22”x 14”x 9”/ 34 lbs
	                                          Remote unit:     6”x 6”x 1”/ 1.8 lb.
	Environmental Specs:       Operating temp:     0°C to 50°C, –40°C to 50°C (optional)
	                                           Storage temp.:       –40°C to 75°C
	                                           Humidity:               5 to 100%
FEATURES
	WiFi-enabled
	RVSM & Automated operation
	Simply enter the target set-points for altitude and airspeed and the unit automatically achieves the targets, ramping at the programmed rates. Control at the set-point is stable within ± 1 foot and ± 0.1 knot. This RVSM tester’s low price makes it very affordable.
Calibration period
	1 year
Programmable limits
	User-programmable limits for altitude, airspeed, Mach, VSI and airspeed-rate provide protection to the aircraft.
Negative-airspeed protection
	An internal differential-pressure relief valve provides protection against negative airspeed.
	Removable Battery (Optional)
	The removable battery allows for 6 to 8 hours of continuous operation. Re-charge time is only 8 hours.
	Low-temperature operation (optional)
	With optional internal heaters, the unit can be operated down to -40°C
	“Jog” and “Hold” features
	Set-points can be “jogged” up or down in small increments. Ramping to a set-point can be put on “hold” and controlled at the current measured value.
	“Ground” feature
	Brings Pitot and Static outputs to ambient “ground” pressure after completing a test. Ambient pressure is constantly monitored.
	“Profiles” feature
	A profile of set-points can be downloaded from a PC, allowing the user to step through the set-points using a single key. Each profile can have up to 50 set-points and 15 profiles can be stored in the unit.
	Leak checks
	Pitot and Static leak-checks can be performed either independently or simultaneously. Three leak-timers can be programmed to perform timed leaks between 1 to 20 minutes. The display of “instant” leak rates provides immediate feedback to the user.
	Pressure & Vacuum source
	Built-in diaphragm pumps provide the pressure and vacuum source for the unit.
	Remote unit
	The Remote unit is the operator interface for the tester. It features a sunlight-readable 5.8” color display, a back-lit keypad and a touch-screen (which can be disabled). All operations are performed from a single screen which displays all pertinent parameters.
	Manual Vent Valves
	On loss of power, the unit maintains pressure. The unit can be manually vented to “Ground” at a controlled rate using precision metering valves.
	Applications
	APPLICATIONS
	Leak-checks and accuracy-checks on Commercial, Business and Military aircraft
	Leak-checks and accuracy-checks on Helicopters and UAVs
	Ideal for heavy-maintenance and line-maintenance by commercial airlines
	银飞 sells Laversab 6300