Keithley6514Programmable Electrometer

Keithley6514Programmable Electrometer.The Model 6514 Electrometer combines flexible interfacing capabilities with current sensitivity, charge measurement capabilities, resolution, and speed that are equal or superior to our earlier electrometers. The Model 6514’s built-in IEEE-488, RS-232, and digital I/O interfaces make it simple to configure fully automated, high speed systems for low-level testing.
Keithley6514

The 5½-digit Model 6514 is designed for applications that demand fast

yet precise measurements low currents, voltages from high resistance sources, charges, or high resistances.The Model 6514’s exceptional measurement performance comes at an affordable price. While its cost is comparable with that of many high end DMMs, the 
Model 6514 offers far greater current sensitivity and significantly lower voltage burden (as low as 20µV) than other instruments can provide.
• <1fA noise
• >200TW input impedance on
voltage measurements
• Charge measurements from 10fC
to 20µC
• High speed—up to 1200
readings/second
• Interfaces readily with switches,
computers, and component
handlers
• Cancels voltage and current
offsets easily

R&D on a Budget

The Model 6514 offers the flexibility and sensitivity needed for a wide array of xperiments, providing better data far faster than older electrometer designs. Applications include measuring currents from light detectors and other sensors, beam experiments, and measuring resistances using a current source. In addition to use by researchers in areas such as physics, optics, and materials science, the Model 6514’s affordable price makes it an attractive alternative to high end DMMs for low current measurement applications, such as testing resistance and leakage current in switches, relays, and other components. For more information on how the Model 6514 does this, refer to the section titled 
“Low Voltage Burden.”
The Model 6514 builds on the features and capabilities of the Keithley electrometers that preceded 
it. For example, like those instruments, a built-in constant current source simplifies measuring 
resistance.
Two analog outputs—a 2V output and a preamp output—are available for recording data with stripchart recorders.

Economical Component Testing

Once, electrometers were simply considered too slow to keep up with the high throughput that production test applications demand. The Model 6514 is designed for fast, sensitive measurements, providing speeds up to 1200 readings per second with fast integration or 17 measurements per second with 60Hz line-cycle integration. It offers 10fA resoution on 2nA signals, settling to within 10% of the final value in just 15ms. A normal-mode rejection ratio (NMRR) of 60dB allows making accurate low current measurements, even in the presence of line frequency induced currents, which is a common concern in production floor environments. The instrument’s sensitivity makes it easy to determine the leakage resistance on capacitances up to 10nF or even on higher capacitances when a series resistor is used.While the Model 6514 can be easily operated manually using the front 
panel controls, it can also be externally controlled for automated test applications. Built-in IEEE-488 and RS-232 interfaces make it possible to program all instrument functions over the bus through a computer controller. The instrument’s interfaces also simplify integrating external hardware, such as sources, switching systems, or other instruments, into the test system. A digital I/O interface can be used to link the Model 6514 to many popular component handlers for tight systems integration in binning, sorting, and similar applications.These features make the Model 6514 a powerful, low cost tool for systems designed to test optical devices and leakage resistance on low-value capacitors, switches, and other devices, particularly when the test system already includes a voltage source or when the source current/measure voltage technique is used to determine resistance.

Low Voltage Burden

The Model 6514’s feedback ammeter design minimizes voltage offsets in the input circuitry, which can affect current measurement accuracy. The instrument also allows active cancellation of its input voltage and current offsets, either manually via the front panel controls or over the bus with IEEE-488 commands.

Dark Current Measurements

When measuring dark currents (Figure 1) from a device such as a photodiode, the ammeter reads the sum of two different currents. The first current is the dark current (I D) generated by the detector with no light falling upon the device (in other words, the signal of interest); the second one is the leakage current (I L) generated by the voltage burden (VBURDEN) appearing at the terminals of the ammeter. In a feedback ammeter, the 
primary “voltage burden” is the amplifier offset voltage. This leakage current represents an error current. Without the use of cancellation techniques, I L = VBURDEN/RL. Figure 2 illustrates how the Model 6514’s CAL VOFFSET is adjusted to cancel VBURDEN to within the voltage noise level of a few microvolts, so the measured current is only the true dark current (ID) of the photodiode. In a similar manner, offset currents can also be 
cancelled. Earlier electrometers used an internal numerical correction technique in which the voltage burden was still present, so the measured dark current included the error term I L = VBURDEN/R L.

Voltage Burden and Measurement Error

Electrometers provide current measurement with lower terminal voltage than is possible when making DMM measurements. As shown in Figure 3, DMMs measure current using a shunt resistance that develops a voltage (typically 200mV full-range) in the input circuit. This creates a terminal voltage (VBURDEN) of about 200mV, thereby lowering the measured current.
Electrometers reduce this terminal voltage by using the feedback ammeter configuration illustrated in Figure 1. The Model 6514 lowers this terminal voltage still further—to the level of the voltage noise—by canceling out the small offset voltage that remains, as shown in Figure 2. Any error signals that remain are negligible in comparison to those that can occur when measuring current with a DMM.
银飞 sells Keithley 6514 products
上一篇:ZX8530 LCR Digital Meter 50hz-100khz 34 points measurable
下一篇:ZX8517BT致新LCR数字电桥

专业选型请咨询我们工作人员

全国统一服务热线

0755-23964199
0755-23964499
0755-23964599
0755-86531914

(国内任一地区手机、座机均可拨打)

版权所有:深圳市银飞电子科技有限公司 粤ICP备15021421号

变压器综合测试仪供应商哪家好,电能质量分析仪品牌推荐,多功能校验仪介绍说明,Fluke功率分析仪器价格,数字压力表多少钱

收缩

银飞电子在线客服