Articles

Druck UNIK5000 Pressure Sensing Platform

Druck UNIK5000 Pressure Sensing Platform, Article from Druck, The new UNIK 5000 is a high performance configurable solution to pressure measurement. The use of micromachined silicon technology and analogue circuitry enables best in class performance for stability, low power and frequency response. The new platform enables you to easily build up your own sensor to match your own precise needs. This high performance, configurable solution to pressure measurement employs modular design and lean manufacturing techniques.
Druck UNIK5000 Pressure Sensing Platform
Features
• Ranges from 70 mbar (1 psi) to 700 bar (10000 psi)
• Accuracy to ±0.04% Full Scale (FS) Best Straight Line (BSL)
• Stainless Steel construction
• Frequency response to 3.5 kHz
• High over pressure capability
• Hazardous Area certifications
• mV, mA, voltage and configurable voltage outputs
• Multiple electrical and pressure connector options
• Operating temperature ranges from –55 to +125°C (-67 to +257°F)
• Online configuration tool
UNIK 5000 Specifications 
Operating Pressure Ranges Gauge Ranges: Any zero based range 70 mbar to 70 bar (1 to 1000 psi), Note: All psi values are approximate.
Sealed Gauge: RangesAny zero based range 10 to 700 bar (145 to 10000 psi),
Absolute Ranges: Any zero based range 100 mbar to 700 bar (1.5 to 10000 psi)
Differential Ranges: Wet/Dry Uni-directional or bi-directional 70 mbar to 35 bar (1 to 500 psi)  et/WetUni-directional or bi-directional 350 mbar to 35 bar (5 to 500 psi) Line pressure: 70 bar (1000 psi) maximum.
Barometric Ranges:Barometric ranges are available with a minimum span of 350 mbar (5.1 psi)
Non-Zero Based Ranges:Non-zero based ranges are available. For non-zero based gauge ranges, please contact Druck to discuss your requirements.
Over Pressure
• 10 × FS for ranges up to 150 mbar (2 psi)
• 6 × FS for ranges up to 700 mbar (10 psi)
• 2 × FS for barometric ranges
• 4 × FS for all other ranges (up to 200 bar for ranges ≤70 bar and up to 1200 bar for ranges >70 bar) For differential versions the negative side must not exceed the positive side by more than:
• 6 × FS for ranges up to 150 mbar (2 psi)
• 4 × FS for ranges up to 700 mbar (10 psi)
• 2 × FS for all other ranges up to a maximum of 15 bar (200 psi)
Containment Pressure
• Ranges up to 150 mbar (2 psi) gauge 10 x FSRanges up to 70 bar (1000 psi) gauge 6 x FS(200 bar (2900 psi) max)
• Ranges up to 70 bar (1000 psi) absolute 200 bar (2900 psi)
• Ranges above 70 bar (1000 psi)
• 1200 bar (17400 psi)*Differential (-ve port) must not exceed positive port by more than 6 × FS (15 bar (200 psi) maximum.600 bar (8700 psi) for pressure connector options PX, RA and RF.
Shunt Calibration
Shunt Calibration provides a customer accessible connection which, when applied, causes a shift in output of 80% FS in order to simulate applied pressure. It is fitted to the mV, Configurable 4-wire and Configurable 3-wire versions as standard. It is not available with DIN, M12 x 1 or M20 x 1.5 electrical connectors (options 7, D, G and R).Shunt calibration is activated in different ways depending on the electrical connector and version:mV versions: connect Shunt Cal to -ve Supply or where available, connect both Shunt Cal connections together.Configurable 4-wire and Configurable 3-wire versions: connect Shunt Cal to -ve Output or, wherea vailable, connect both Shunt Cal connections together.Note: Not available with reverse output
Druck UNIK5000 Pressure Sensing Platform combinatorial
Performance Specifications
There are three grades of performance specification: Industrial, Improved and Premium.Voltage, Current and mV Linearised Combined effects of non-linearity, hysteresis and repeatability:
• Industrial: ±0.2% FS BSL
• Improved: ±0.1% FS BSL
• Premium: ±0.04% FS BSL
mV Passive ≤ 70 bar Industrial/Improved: ±0.25% FS BSL Premium not available > 70 bar.Industrial/Improved: ±0.5% FS BSL Premium not available Note 1: For the barometric pressure range, accuracy is of span, not full scale. Note 2: For bi-directional ranges, accuracy is specified for each direction separately.
Zero Offset and Span Setting
Demountable electrical connector options allow access to potentiometers that give at least ±5% FS adjustment (see Electrical Connector section).
Physical Specifications
Environmental Protection See Electrical Connector section Hyperbaric Pressure: 20 bar (300 psi) maximum
Operating Temperature Range:See Electrical Connector section
Pressure Media:Fluids compatible with stainless steel 316L and Hastelloy C276. For the wet/dry differential version, negative pressure port: Fluids compatible with stainless steel 316L, stainless steel 304, Pyrex, silicon and structural adhesive.
Enclosure Materials
Stainless steel (body), nitrile- or silicone-rubber (o-rings, gaskets), EPDM (gaskets), PVDF (depth cone), PTFE (vent filter), Nickel plated brass (lock rings), glass filled nylon (electrical connector assemblies), delrin (depth cone). Cable sheaths as specified (see Electrical Connector).
Pressure Connector
Available options are:
• G1/4 Female
• G1/4 Male Flat
• G1/4 Male 60° Internal Cone
• G1/4 Male Flat Long
• G1/4 Male Flat with Snubber
• G1/4 Male Flat with Cross Bore Protection
• G1/4 Male with Nipple
• G1/4 Quick Connect
• G1/8 Male 60° Internal Cone
• G1/2 Male via Adaptor
• 1/4 NPT Female
• 1/4 NPT Male
• 1/8 NPT Male
• 1/8-27 NPT Female
• 1/2 NPT Male via Adaptor
• 7/16-20 UNJF Female
• 7/16-20 UNF Male Short Flat
• 7/16 UNF Long 37° Flare Tip
• 7/16-20 UNJF Male 74° External Cone
• 3/8-24 UNJF
• 1/4 Swagelok Bulkhead
• M10 X 1 80° Internal Cone
• M12 X 1 60° Internal Cone
• M14 X 1.5 60° Internal Cone
• M20 X 1.5 Male (3 mm bore)
• M20 X 1.5 Male (8 mm bore)
• Depth Cone (G1/4 Female Open Face)
• M12 x 1.0 74° External Cone
• Quick Release Male
• VCR Female
• VCR Male
• NW16 Flange
• R3/8 Male
• R1/4 Male
Choose connectors marked for pressure ranges over 70 bar. Other pressure connectors may be available, contact Druck to discuss your requirement.General Certifications CRN Certified 0F13650.517890YTN ADD1/REV1, 0F13828.2 (sensor types K and O) and CSA 0F13650.56 ADD1 for pressure ranges up to and including 350 bar (5000 psi).
CE Conformity
• RoHS 2011/65/EU
• Pressure Equipment Directive 2014/68/EU Sound Engineering Practice
• ATEX 2014/34/EU (Optional)
• EMC Directive 2014/30/EU
• BS EN 61000-6-1: 2007: Susceptibility - Light Industrial
• BS EN 61000-6-2: 2005: Susceptibility - Heavy Industrial
• BS EN 61000-6-3: 2007+A1:2011: Emissions - Light Industrial
• BS EN 61000-6-4: 2007+A1:2011: Emissions - Heavy Industrial
• BS EN 61326-1: 2013: Electrical Equipment for Measurement, Control and Laboratory Use
• BS EN 61326-2-3: 2013: Particular Requirements for Pressure Transducers PMP/PTX models with electrical connector options 6, A, C, E, F, G, N and R with cable screen connected to case.
Shenzhen Yinfei has Druck UNIK5000 Pressure Sensing Platform for sale.